{"product_id":"apc-smx2200rmlv2u-uninterruptible-power-supply-ups-2-2-kva-1980-w","title":"APC SMX2200RMLV2U uninterruptible power supply (UPS) 2.2 kVA 1980 W","description":"\u003cb\u003eIntuitive LCD interface\u003c\/b\u003e\u003cbr\u003eProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHigh frequency design\u003c\/b\u003e\u003cbr\u003eReduces or eliminates bulky transformers resulting in lighter units for ease of handling.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAuto recognition of external batteries\u003c\/b\u003e\u003cbr\u003eUPS recognizes when external battery packs are attached and automatically adjusts runtime.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePredictive replace battery date\u003c\/b\u003e\u003cbr\u003eDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eGreen mode\u003c\/b\u003e\u003cbr\u003ePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEnergy meter\u003c\/b\u003e\u003cbr\u003eProvides actual kilowatt hours of usage for energy conscious users.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOutlet group control\u003c\/b\u003e\u003cbr\u003eTurn on\/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSequenced shutdown and restart\u003c\/b\u003e\u003cbr\u003eConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLoad shedding\u003c\/b\u003e\u003cbr\u003eTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePure sine wave output on battery\u003c\/b\u003e\u003cbr\u003eSimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eMultiple switched outlet groups\u003c\/b\u003e\u003cbr\u003eMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on\/off and non-critical load shedding.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWide input voltage range\u003c\/b\u003e\u003cbr\u003eDesigned for harsh electrical environments to save battery life.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eStruxureWare Central compatible\u003c\/b\u003e\u003cbr\u003eEnables centralized management via StruxureWare Central.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBattery failure notification\u003c\/b\u003e\u003cbr\u003eProvides early-warning fault analysis on batteries enabling timely preventive maintenance\u003cbr\u003eHigh online efficiency Reduces utlility costs, generates less heat.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLED Indicators\u003c\/b\u003e\u003cbr\u003eProvide easy-to-read status of the unit and utility power conditions.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOverload protection\u003c\/b\u003e\u003cbr\u003eSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSmartSlot\u003c\/b\u003e\u003cbr\u003eCustomize UPS capabilities with management cards.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCold-start capable\u003c\/b\u003e\u003cbr\u003eProvides temporary battery power when the utility power is out.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHot-swappable batteries\u003c\/b\u003e\u003cbr\u003eEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDisconnected battery notification\u003c\/b\u003e\u003cbr\u003eWarns when a battery is not available to provide backup power.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic self-test\u003c\/b\u003e\u003cbr\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic restart of loads after UPS shutdown\u003c\/b\u003e\u003cbr\u003eAutomatically starts up the connected equipment upon the return of utility power.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage-transfer points\u003c\/b\u003e\u003cbr\u003eMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage sensitivity\u003c\/b\u003e\u003cbr\u003eProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAudible alarms\u003c\/b\u003e\u003cbr\u003eProvides notification of changing utility power and UPS conditions\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUser-replaceable batteries\u003c\/b\u003e\u003cbr\u003eIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUSB connectivity\u003c\/b\u003e\u003cbr\u003eProvides management of the UPS via a USB port (not available on all models).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSerial Connectivity\u003c\/b\u003e\u003cbr\u003eProvides management of the UPS via a serial port.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eTemperature-compensated battery charging\u003c\/b\u003e\u003cbr\u003eProlongs battery life by regulating the charge voltage according to battery temperature.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBoost and Trim Automatic Voltage Regulation (AVR)\u003c\/b\u003e\u003cbr\u003eGives higher application availability by correcting low and high voltage conditions without using the battery.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eScalable runtime\u003c\/b\u003e\u003cbr\u003eAllows additional run time to be quickly added as needed.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIntelligent battery management\u003c\/b\u003e\u003cbr\u003eMaximizes battery performance, life, and reliability through intelligent, precision charging.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSafety-agency approved\u003c\/b\u003e\u003cbr\u003eEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRack\/Tower convertible\u003c\/b\u003e\u003cbr\u003eProtects the initial investment in the UPS when migrating from tower to rack-mount environment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePower conditioning\u003c\/b\u003e\u003cbr\u003eProtects connected loads from surges, spikes, lightning, and other power disturbances.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eNetwork manageable\u003c\/b\u003e\u003cbr\u003eProvides remote management of the UPS over the network.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFrequency and voltage regulation\u003c\/b\u003e\u003cbr\u003eGives higher application availability by correcting poor frequency and voltage conditions without using the battery.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePredicitive failure notification\u003c\/b\u003e\u003cbr\u003eProvides early-warning fault analysis ensuring proactive component replacement.","brand":"APC by Schneider Electric","offers":[{"title":"Default Title","offer_id":44234643079303,"sku":"SMX2200RMLV2U","price":3125.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/0926\/5031\/files\/img_10980925_medium_1481699770_7604_12896.jpg?v=1774053277","url":"https:\/\/anyteks.ca\/products\/apc-smx2200rmlv2u-uninterruptible-power-supply-ups-2-2-kva-1980-w","provider":"anyteks.ca","version":"1.0","type":"link"}